| Novatech

F241 Axial Compensated Loadcell

Standard Ranges 30, 50, 100 and 300N (3 to 30kgf)

  • High accuracy
  • Easy installation
  • Misalignment error compensation
  • Standard 1 year warranty
  • Integral overload protection option
  • Traceable calibration with certificate included in the standard price

Specification

Parameter

Value

Unit

Non-linearity - Terminal

±0.05

% RL

Hysteresis

±0.05

% RL

Creep - 20 minutes

±0.02

% AL

Repeatability

±0.02

% RL

Rated output - Nominal

2.2

mV/V

Rated output - Rationalised

2.0

mV/V

Rationalisation tolerance (applies to single direction calibrations)

±0.1

% RL

Zero load output

±4

% RL

Temperature effect on rated output per °C

±0.005

% AL

Temperature effect on zero load output per °C

±0.005

% RL

Temperature range - Compensated

-10 to +50

°C

Temperature range - Safe

-10 to +80

°C

Excitation voltage - Recommended

10

V

Excitation voltage - Maximum

10

V

Bridge resistance

350

Ω

Insulation resistance - Minimum at 50Vdc

500

MΩ

Overload - Safe

20

% RL

Overload - Ultimate

100

% RL

Weight - Nominal (excluding cable)

240 to 260

g

All standard ranges are manufactured in aluminium.

Geometry: Flexure strain assembly in cylindrical housing, open or weather sealed with end internal fixing. For universal use in tension and compression, with compensation for off axis load inputs.

The F241 is ideally suited to low range engineering force measurements and process weighing. When precision and easy installation are required various configurations allow the loadcell to be used in both tensile and compressive applications.

We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for higher temperature operation. Please consult our engineering department.

Order Codes

Code

Description

F241CF00H0

Compression, unrationalised

F241TF00H0

Tension, unrationalised

F241UF00H0

Bi-directional, unrationalised

F241CF00HN

Compression, rationalised

F241TF00HN

Tension, rationalised

F241UF00HN

Bi-directional, rationalised

Change the C to a D for compression with thread fitting.

Structural Stiffness - Nominal

Range (N)

Stiffness (N/m)

30

1.5 x 105

50

2.5 x 105

100

5.0 x 105

300

1.5 x 106

Notes

  • AL = Applied load.
  • RL = Rated load.
  • Temperature coefficients apply over the compensated range.

Connections

The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

Reverse the signal connections to obtain a positive signal in tension mode. The screen is not connected to the loadcell body.