| Novatech

F225 High Load Ultra Low Profile Loadcell

Standard Ranges 50 and 100kN (5 and 10tonnef)

  • Ultra low profile
  • Fail-safe failure mode
  • Hardened stainless steel
  • IP67 sealing option
  • Traceable calibration with certificate included in the standard price
  • Standard 1 year warranty

Specification

Parameter

Value

Unit

Non-linearity - Terminal

±0.5

% RL

Hysteresis

±0.5

% RL

Creep - 20 minutes

±0.05

% AL

Repeatability

±0.02

% RL

Rated output - Nominal

2.3

mV/V

Rated output - Rationalised

2.0

mV/V

Rationalisation tolerance

±0.5

% RL

Zero load output

±4

% RL

Temperature effect on rated output per °C

±0.005

% AL

Temperature effect on zero load output per °C

±0.005

% RL

Temperature range - Compensated

-10 to +50

°C

Temperature range - Safe

-10 to +80

°C

Excitation voltage - Recommended

10

V

Excitation voltage - Maximum

10

V

Bridge resistance

350

Ω

Insulation resistance - Minimum at 50Vdc

500

MΩ

Overload - Safe

50

% RL

Overload - Ultimate

300

% RL

Sealing - R option

IP65

Sealing - S option

IP67

Weight - Nominal (excluding cable)

0.8

kg

Geometry: Ultra low profile axial loadcell for use in force measurements in compression.

The ultra slim design provides for ease of installation beneath heavy machinery mounts, hydraulic rams or interposed within series mechanical compression assemblies.

In the event of structural failure of the loadcell the resulting vertical movement of the supported load including normal deflection will not exceed 2.5mm.

We are happy to design variants of this loadcell to meet your specific requirements. Please consult our engineering department.

Order Codes

Code

Description

F225CFR0H0

Compression, IP65, unrationalised

F225CFR0HN

Compression, IP65, rationalised

Change the R to an S for IP67 sealing.

Structural Stiffness - Nominal

Range (kN)

Stiffness (N/m)

50

2.1 x 1010

100

4.2 x 1010

Notes

  • AL = Applied load.
  • RL = Rated load.
  • Temperature coefficients apply over the compensated range.
  • The load must be applied directly through the central loading axis.

Connections

The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C.

Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.

The screen is not connected to the loadcell body.

Files

Type

Title

Download

Outline

Outline drawing of the product.

Download

STEP File

F225CFR0K0 All standard ranges

Download