The ultra slim design provides for ease of installation beneath heavy machinery mounts, hydraulic rams or interposed within series mechanical compression assemblies.
In the event of structural failure of the loadcell the resulting vertical movement of the supported load including normal deflection will not exceed 2.5mm.
We are happy to design variants of this loadcell to meet your specific requirements. Please consult our engineering department.
The ultra slim design provides for ease of installation beneath heavy machinery mounts, hydraulic rams or interposed within series mechanical compression assemblies.
In the event of structural failure of the loadcell the resulting vertical movement of the supported load including normal deflection will not exceed 2.5mm.
We are happy to design variants of this loadcell to meet your specific requirements. Please consult our engineering department.
Parameter | Value | Unit |
---|---|---|
Non-linearity - Terminal | ±0.5 | % RL |
Hysteresis | ±0.5 | % RL |
Creep - 20 minutes | ±0.05 | % AL |
Repeatability | ±0.02 | % RL |
Rated output - Nominal | 2.3 | mV/V |
Rated output - Rationalised | 2.0 | mV/V |
Rationalisation tolerance | ±0.5 | % RL |
Zero load output | ±4 | % RL |
Temperature effect on rated output per °C | ±0.005 | % AL |
Temperature effect on zero load output per °C | ±0.005 | % RL |
Temperature range - Compensated | -10 to +50 | °C |
Temperature range - Safe | -10 to +80 | °C |
Excitation voltage - Recommended | 10 | V |
Excitation voltage - Maximum | 10 | V |
Bridge resistance | 350 | Ω |
Insulation resistance - Minimum at 50Vdc | 500 | MΩ |
Overload - Safe | 50 | % RL |
Overload - Ultimate | 300 | % RL |
Sealing - R option | IP65 | |
Sealing - S option | IP67 | |
Weight - Nominal (excluding cable) | 0.8 | kg |
Code | Description |
---|---|
F225CFR0H0 | Compression, IP65, unrationalised |
F225CFR0HN | Compression, IP65, rationalised |
Change the R to an S for IP67 sealing. |
Range (kN) | Stiffness (N/m) |
---|---|
50 | 2.1 x 1010 |
100 | 4.2 x 1010 |