F238 Binocular Bending Beam
Standard Ranges 50, 100 and 300N (5 to 30kgf)
- Tension / compression / bi-directional calibration
- Easy installation
- Small size single point loadcell
- Standard 1 year warranty
- All aluminium construction
- Traceable calibration with certificate included in the standard price
Specification
Parameter | Value | Unit |
Non-linearity - Terminal | ±0.05 | % RL |
Hysteresis | ±0.05 | % RL |
Creep - 20 minutes | ±0.05 | % AL |
Repeatability | ±0.02 | % RL |
Rated output - Nominal | 2.2 | mV/V |
Rated output - Rationalised | 2.0 | mV/V |
Rationalisation tolerance (applies to single direction calibrations) | ±0.1 | % RL |
Zero load output | ±4 | % RL |
Temperature effect on rated output per °C | ±0.002 | % AL |
Temperature effect on zero load output per °C | ±0.005 | % RL |
Temperature range - Compensated | -10 to +50 | °C |
Temperature range - Safe | -10 to +80 | °C |
Excitation voltage - Recommended | 10 | V |
Excitation voltage - Maximum | 10 | V |
Bridge resistance | 350 | Ω |
Insulation resistance - Minimum at 50Vdc | 500 | MΩ |
Overload - Safe | 20 | % RL |
Overload - Ultimate | 100 | % RL |
All standard ranges are manufactured in aluminium.
The F238 is a compact binocular bending beam loadcell for force measurements. This type of binocular beam is often referred to as a single point loadcell.
The binocular bending beam construction has good moment immunity resulting in very small errors for change in the force application point.
We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for higher temperature operation. Please consult our engineering department.
Order Codes
Code | Description |
F238CF00H0 | Compression, unrationalised |
F238TF00H0 | Tension, unrationalised |
F238UF00H0 | Bi-directional, unrationalised |
F238CF00HN | Compression, rationalised |
F238TF00HN | Tension, rationalised |
F238UF00HN | Bi-directional, rationalised |
Structural Stiffness - Nominal
Range (N) | Stiffness (N/m) |
50 | 4.3 x 104 |
100 | 8.6 x 104 |
300 | 1.3 x 105 |
Notes
- AL = Applied load.
- RL = Rated load.
- Temperature coefficients apply over the compensated range.
Connections
The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C.
Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.
Reverse the signal connections to obtain a positive signal in tension mode. The screen is not connected to the loadcell body.