F216 Loadcell
Standard Ranges 5, 10, 20 and 40kN (500kgf to 4tonnef)
- Hardened stainless steel body
- Standard 1 year warranty
- High mechanical stiffness
- Flying lead
- Small size
- Traceable calibration with certificate included in the standard price
Specification
Parameter | Value | Unit |
Non-linearity - Terminal | ±0.5 | % RL |
Hysteresis | ±0.5 | % RL |
Creep - 20 minutes | ±0.05 | % AL |
Repeatability | ±0.02 | % RL |
Rated output - Nominal | 1.2 | mV/V |
Rated output - Rationalised | 1.0 | mV/V |
Rationalisation tolerance | ±0.5 | % RL |
Zero load output | ±4 | % RL |
Temperature effect on rated output per °C | ±0.005 | % AL |
Temperature effect on zero load output per °C | ±0.03 | % RL |
Temperature range - Compensated | -10 to +50 | °C |
Temperature range - Safe | -10 to +80 | °C |
Excitation voltage - Recommended | 10 | V |
Excitation voltage - Maximum | 20 | V |
Bridge resistance | 700 | Ω |
Insulation resistance - Minimum at 50Vdc | 500 | MΩ |
Overload - Safe | 50 | % RL |
Overload - Ultimate | 400 | % RL |
Sealing | IP65 | |
Weight - Nominal (excluding cable) | 90 to 100 | g |
Geometry: Axial strain cylinder in weather sealed case, with raised end load bearing faces. For use in compression.
The F216 is ideally suited to engineering force measurements. It is designed for easy installation, usually between two flat faces bearing on its loading rings.
The small size of this loadcell makes it an ideal force sensor for mounting in existing machinery. It has been used in presses and printing machines.
We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for fully compensated operation up to +250°C. Please consult our engineering department.
Order Codes
Code | Description |
F216CFR0K0 | Compression, IP65, unrationalised |
F216CFR0KN | Compression, IP65, rationalised |
Structural Stiffness - Nominal
Range (kN) | Stiffness (N/m) |
5 | 2.4 x 108 |
10 | 4.8 x 108 |
20 | 9.6 x 108 |
40 | 1.9 x 109 |
Notes
- AL = Applied load.
- RL = Rated load.
- Temperature coefficients apply over the compensated range.
- The load must be applied directly through the central loading axis.
Connections
The loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-2-4C.
Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.
The screen is not connected to the loadcell body.