The loadcell is deliberately over engineered to achieve a low contact surface pressure under high loading.
Smaller column type loadcells, such as the F218, are available and we can cover the F327 load ranges with smaller designs. Please consult our engineering department.
The loadcell is deliberately over engineered to achieve a low contact surface pressure under high loading.
Smaller column type loadcells, such as the F218, are available and we can cover the F327 load ranges with smaller designs. Please consult our engineering department.
Parameter | Value | Unit |
---|---|---|
Non-linearity - Terminal | ±0.05 (10 - 50kN) / ±0.1 (100 - 1000kN) / ±0.4 (2000kN) | % RL |
Hysteresis | ±0.05 (10 - 50kN) / ±0.4 (100 - 1000kN) / ±0.4 (2000kN) | % RL |
Creep - 20 minutes | ±0.05 (10 - 50kN) / ±0.05 (100 - 1000kN) / ±0.05 (2000kN) | % AL |
Repeatability (excluding rotational effects)* | ±0.02 (10 - 50kN) / ±0.03 (100 - 1000kN) / ±0.03 (2000kN) | % RL |
Rated output - Nominal | 1.2 (10 - 50kN) / 1.2 (100 - 1000kN) / 1.2 (2000kN) | mV/V |
Rated output - Rationalised | 1.0 (10 - 50kN) / 1.0 (100 - 1000kN) / 1.0 (2000kN) | mV/V |
Rationalisation tolerance | ±0.5 (10 - 50kN) / ±0.5 (100 - 1000kN) / ±0.5 (2000kN) | % RL |
Zero load output | ±4 (10 - 50kN) / ±4 (100 - 1000kN) / ±4 (2000kN) | % RL |
Temperature effect on rated output per °C | ±0.005 (10 - 50kN) / ±0.005 (100 - 1000kN) / ±0.005 (2000kN) | % AL |
Temperature effect on zero load output per °C | ±0.01 (10 - 50kN) / ±0.01 (100 - 1000kN) / ±0.01 (2000kN) | % RL |
Temperature range - Compensated | -10 to +50 | °C |
Temperature range - Safe | -10 to +80 | °C |
Excitation voltage - Recommended | 10 (10 - 50kN) / 10 (100 - 1000kN) / 10 (2000kN) | V |
Excitation voltage - Maximum | 20 (10 - 50kN) / 20 (100 - 1000kN) / 20 (2000kN) | V |
Bridge resistance | 700 (10 - 50kN) / 700 (100 - 1000kN) / 700 (2000kN) | Ω |
Insulation resistance - Minimum at 50Vdc | 500 (10 - 50kN) / 500 (100 - 1000kN) / 500 (2000kN) | MΩ |
Overload - Safe | 50 (10 - 50kN) / 50 (100 - 1000kN) / 50 (2000kN) | % RL |
Overload - Ultimate | 200 (10 - 50kN) / 200 (100 - 1000kN) / 200 (2000kN) | % RL |
Sealing | IP67 | |
Weight - Nominal (excluding cable) | 1.6 (10 - 50kN) / 8 to 24.1 (100 - 1000kN) / 28.3 (2000kN) | kg |
Code | Description |
---|---|
F327CFS0K0 | Compression, IP67, unrationalised |
F327CFS0KN | Compression, IP67, rationalised |
Change the F to a P for the connector version. |
Range (kN) | Stiffness (N/m) |
---|---|
10 | 2.2 x 108 |
20 | 4.3 x 108 |
50 | 1.1 x 109 |
100 | 1.6 x 109 |
200 | 3.2 x 109 |
500 | 8.1 x 109 |
1000 | 8.3 x 109 |
2000 | 8.7 x 109 |
Title | Type | File |
---|---|---|
Outline drawing of the product. | Outline | Download |
F327CFS0K0 10 to 50kN (1 to 5tonnef) | STEP File | Download |
F327CFS0K0 100 to 500kN (10 to 50tonnef) | STEP File | Download |
F327CFS0K0 1000 to 2000kN (100 to 200tonnef) | STEP File | Download |
F327CPS0K0 10 to 50kN (1 to 5tonnef) | STEP File | Download |
F327CPS0K0 100 to 500kN (10 to 50tonnef) | STEP File | Download |
F327CPS0K0 1000 to 2000kN (100 to 200tonnef) | STEP File | Download |