T24-ACM/SA Loadcell Telemetry Data Acquisition Unit

This remote loadcell data acquisition unit provides high performance wireless measurement of loadcell outputs. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells.

Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or a base station.

The data acquisition unit uses a pair of standard alkaline D cells and is configured using free T24 Toolkit software which runs on a computer connected to a T24 base station. External powering is also possible with a suitable dc power supply. Using good quality alkaline batteries, a 700ohm loadcell, a 100ms sample time at 3 readings a second with 24 hours a day operation the battery life is approximately 18 days. The Toolkit software will calculate typical battery life for a given set of conditions.

Loadcell connections are via field terminals. Full details are given in the manual.

If the unit is supplied with a loadcell it will normally be calibrated to read the loadcell output in the same force units as the loadcell calibration. A traceable system certificate will be supplied for this calibration. The loadcell and this unit are the only parts of the telemetry system that require calibration.

Alternative calibrations are possible; please consult our engineering department to discuss your requirements.

Complies with EMC directive, 2004/108/ECThe Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive, 1999/5/EC. RoHS compliant.

Low power modes allow the module to power down between transmissions or to power off completely and can be controlled by other T24 products such as the handheld displays or a base station.

The data acquisition unit uses a pair of standard alkaline D cells and is configured using free T24 Toolkit software which runs on a computer connected to a T24 base station. External powering is also possible with a suitable dc power supply. Using good quality alkaline batteries, a 700ohm loadcell, a 100ms sample time at 3 readings a second with 24 hours a day operation the battery life is approximately 18 days. The Toolkit software will calculate typical battery life for a given set of conditions.

Loadcell connections are via field terminals. Full details are given in the manual.

If the unit is supplied with a loadcell it will normally be calibrated to read the loadcell output in the same force units as the loadcell calibration. A traceable system certificate will be supplied for this calibration. The loadcell and this unit are the only parts of the telemetry system that require calibration.

Alternative calibrations are possible; please consult our engineering department to discuss your requirements.

Complies with EMC directive, 2004/108/ECThe Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive, 1999/5/EC. RoHS compliant.

Specification

ParameterValueUnit
Battery voltage2.1 (Min) / 3 (Typical) / 3.6 (Max)Vdc
External dc supply5 (Min) / 18 (Max)Vdc
Bridge Excitation4.5 (Min) / 5 Typical / 5.25 (Max)Vdc
Loadcell Excitation System4 wire
Bridge Impedance85 (Min) / 5,000 (Max)Ohms
Bridge Sensitivity-3.2 (Min) / +3.2 (Max)mV/V
Offset Temperature Stability1 (Typical) / 4 (Max)ppm/°C
Gain Temperature Stability3 (Typical) / 5 (Max)ppm/°C
Offset Stability with Time0.002 (Typical) / 0.008 (Max)%FR *
Gain Stability with Time30ppm of FR /1st Year
Non-linearity0.0005 (Typical) / 0.0025 (Max)% FR
Internal Resolution16 MillionCounts/Divisions
Resolution at 1000ms sample time *250,000Counts/Divisions
Resolution at 100ms sample time *120,000Counts/Divisions
Resolution at 10ms sample time *50,000Counts/Divisions
Maximum loadcell cable length3m
Operating temperature range-20 (Min) / 55 (Max)°C
Storage temperature-40 (Min) / 85 (Max)°C
Humidity0 (Min) / 95 (Max)%RH Non condensing
SealingIP67

Order Codes

CodeDescription
T24-ACM/SACased battery powered loadcell data acquisition unit.
T24 manual is available for download. The T24 system can be calibrated in a number of different ways depending upon the application. Please consult our engineering department for help with your requirements.
Please see Engineering Sheet E035 for Frequently Asked Questions for the T24 Telemetry system.

Notes

  • * Noise free.
  • FR = full range.
  • RH = relative humidity.
  • Line of sight transmission distance assumes ideal conditions with the data acquisition unit 3m above the ground.
  • The batteries used may reduce the operating temperature range. Storage temperature is without batteries.

Files

TitleTypeFile
Diagram of the productDiagram Download
Printable manual for the T24 system.PDF Instructions Download

Enquire about T24-ACM/SA Loadcell Telemetry Data Acquisition Unit

Related Products

TR150 Portable Loadmeter

The TR150 is a completely portable, precision instrument packaged in a small, robust IP65 (NEMA 4) enclosure, weighing only 260 grams. The TR150 accepts an input range of up to 50mV/V.

DSC USB Loadcell Digitiser

The DSC USB is a compact, high performance digital signal conditioner with USB connectivity aimed at applications, which require high-accuracy measurement repeatability.

FSU-SSBD Fast Loadcell Digitiser

The FSU-SSBD is a fast, compact, high precision loadcell input module delivering high resolution readings over USB and communicated directly to a PC.

SGA/A and SGA/D Loadcell Amplifier

The SGA loadcell amplifier is designed for use with strain gauge loadcells. It provides industry standard current or voltage outputs for accurate interfacing of loadcells with control and monitoring systems.

ICA6H Loadcell Amplifier

This miniature loadcell amplifier is designed for use with strain gauge loadcells. It has a bi-polar ±10V output for use with bi-directional loadcells even though it is powered from a uni-polar supply.

LCA20 Loadcell Amplifier

The LCA15 has been redesigned to become the LCA20 taking advantage of new technology to improve performance and increase functionality.

LCD20 Loadcell Amplifier

The LCD20 intelligent loadcell amplifier is a compact, DIN rail mounted microprocessor based unit for use with strain gauge bridge loadcells in force measuring applications.

TLB DIN rail mounted digital loadcell amplifier

TLB DIN rail mounted digital loadcell amplifier

TLM8 Multi-input digital loadmeter

TLM8 Multi-input digital loadmeter

WLIGHT portable digital loadmeter

WLIGHT portable digital loadmeter

W200 digital loadmeter

W200 digital loadmeter

INT4-L

The versatile INT4-L panel mount loadmeter for strain gauge loadcells

T24-ACM/SA Loadcell Telemetry Data Acquisition Unit

This remote loadcell data acquisition unit provides high performance wireless measurement of loadcell outputs. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells.

T24-ACMi/SA Miniature Loadcell Telemetry Data Acquisition Unit

This miniature loadcell data acquisition unit provides high performance wireless measurement of loadcell outputs. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells.

T24-BSu Loadcell Telemetry Base Station

The base station is a computer interface for the T24 telemetry system that connects to a standard USB port on a computer. It is required for the configuration of all T24 modules.

T24-HA Handheld Telemetry Display Unit

This wireless handheld display module provides an 8 digit LCD reading from up to twelve T24 loadcell data acquisition modules.

T24-HS Handheld Telemetry Display Unit

This wireless handheld display module provides an 8 digit LCD reading from a T24 loadcell data acquisition module.

T24-SYS Loadcell Telemetry System

The T24 telemetry range is a flexible radio telemetry system designed to provide high accuracy measurement data from strain gauge loadcells.

T24-SYSC Set-up Wheel Loadcell Telemetry System

The T24 telemetry range is a flexible radio telemetry system designed to provide high accuracy measurement data from strain gauge loadcells.

SMW Intelligent Loadmeter

This panel or wall mounting loadmeter is designed for use with strain gauge loadcells.

ADW15 Loadmeter

This intelligent self contained loadmeter is designed for use with strain gauge loadcells.

SY011 Loadcell Amplifier

This loadcell amplifier is designed for use with strain gauge loadcells.

SY014 Integral Loadcell Amplifier

This loadcell amplifier is designed for mounting inside the F256 and F257 loadcells.

SY018 Loadcell Amplifier

This DIN rail mounted loadcell amplifier is designed for use with strain gauge loadcells.

SD039 Integral Loadmeter

This small loadmeter is designed for mounting in modified strain gauge loadcells.