Home » Products » Instrumentation » Amplifiers » TLB DIN rail mounted digital loadcell amplifier
A compact digital loadcell amplifier card with digitally derived analogue output for current loop and voltage measuring systems. The TLB includes localised controls and a 6 segment display for easy setup in the field. While taking measurements the display provides a 5½ digit monitor of the load conditions experienced by the TLB to allow for easy system diagnostics. The TLB offers 3 relay outputs to drive trips and alarm indicators, and 2 optoisolated inputs for remote control of the amplifier. Versions are available with a wide range of communications options for CANopen, DeviceNet, CC-Link, Profibus, Modbus, Ethernet, Profinet, EtherCAT, POWERLINK and SERCOS III.
Basic models:
TLB [TLB DIN rail mounted digital loadcell amplifier]
A compact digital loadcell amplifier card with digitally derived analogue output for current loop and voltage measuring systems. The TLB includes localised controls and a 6 segment display for easy setup in the field. While taking measurements the display provides a 5½ digit monitor of the load conditions experienced by the TLB to allow for easy system diagnostics. The TLB offers 3 relay outputs to drive trips and alarm indicators, and 2 optoisolated inputs for remote control of the amplifier. Versions are available with a wide range of communications options for CANopen, DeviceNet, CC-Link, Profibus, Modbus, Ethernet, Profinet, EtherCAT, POWERLINK and SERCOS III.
Basic models:
TLB [TLB DIN rail mounted digital loadcell amplifier]
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 10 to 26 | Vdc |
| Supply current | 250 | mA |
| Operating temperature | -20 to 60 | °C |
| Storage temperature | -30 to +80 | °C |
| Dimensions | 115x25x120 | mm |
| Display | 8mm high 5½ digit red LED | |
| Measuring A/D converter | 24 | bit |
| Conversion rate | Up to 300 readings | per second |
| Thermal stability | 0.0005% full scale | °C |
| Non-linearity | 0.01% of full scale | |
| Loadcell input | 4 wire and 6 wire with remote sensing | |
| Excitation supply | 5 ±0.1 | V |
| Bridge resistance range | 85 to 5000 | Ω |
| Sensitivity range | 0.5 to 7.0 | mV/V |
| Analogue output A/D converter | 16 | bit |
| Analogue output non-linearity | 0.01% | of full range |
| Analogue output thermal stability | 0.003% | full scale/°C |
| Analogue output options | 0mA to 20mA, 4mA to 20mA, 0V to 5V, 0V to 10V, ±5V, ±10V | |
| Maximum current loop resistance | 300 | Ω |
| Minimum voltage output load resistance | 10k | Ω |
| Digital inputs | 2 optoisolated 5-24Vdc | |
| Relay outputs | 3 rated at 115Vac, 150mA | |
| Communications | RS485 serial port, ModBus RTU, ASCII |