Home » Products » Instrumentation » Amplifiers » SY011 Loadcell Amplifier
It provides industry standard current or voltage outputs for accurate interfacing of loadcells with control and monitoring systems.
This amplifier is ideally suited to engineering applications. Its small size makes it easy to mount inside existing equipment.
The voltage output version of the amplifier has a bi-polar output for use with bi-directional loadcells even though it is powered from a uni-polar supply.
The amplifier is easily calibrated using non-interactive zero and span trimmers. When it is purchased with a loadcell it will be calibrated for use with the loadcell.
If the SY011 is supplied with a loadcell it will normally be calibrated to read the loadcell output in the same force units as the loadcell calibration. A traceable system certificate will be supplied for the amplifier and loadcell combination.
CE – This instrumentation product complies with the requirements of the European EMC directive.
It provides industry standard current or voltage outputs for accurate interfacing of loadcells with control and monitoring systems.
This amplifier is ideally suited to engineering applications. Its small size makes it easy to mount inside existing equipment.
The voltage output version of the amplifier has a bi-polar output for use with bi-directional loadcells even though it is powered from a uni-polar supply.
The amplifier is easily calibrated using non-interactive zero and span trimmers. When it is purchased with a loadcell it will be calibrated for use with the loadcell.
If the SY011 is supplied with a loadcell it will normally be calibrated to read the loadcell output in the same force units as the loadcell calibration. A traceable system certificate will be supplied for the amplifier and loadcell combination.
CE – This instrumentation product complies with the requirements of the European EMC directive.
Parameter | Value | Unit |
---|---|---|
Output | Current version: 4 to 20mA, loop resistance <400Ω (24V supply). Voltage version: ±5V or ± 10V, load resistance >10kΩ | |
Sensitivity | Factory set between 0.5 and 100mV/V | |
Non-linearity - typical | ±0.05% of full range | |
Drift - typical | Zero: 0.5µV/°C at the input. Span: 80ppm/°C | |
Supply requirements | Nominal 24Vdc (17 to 30Vdc) | |
Maximum supply current | 120mA | |
Loadcell supply | 5Vdc (15mA) or 10Vdc (30mA) (factory set) | |
Operating Temperature | 0 to +50°C | |
Case material | ABS | |
Case dimensions | 100 x 49 x 20 mm (including terminals) |
Code | Description |
---|---|
SY011ABCD - Replace A, B, C and D with the required codes from the list below. | |
A (Basic type) | V for voltage output, I for current output. |
B (Amplifier output) | 005 for ±5, 010 for ±10V, 420 for 4 to 20mA. |
C (Loadcell excitation voltage) | 05 for 5V, 10 for 10V. |
D (Loadcell output in mV/V) | Usually 1.0 or 2.0, other values are possible. |
Example: SY011I-420-10-2.0 This has a 4 to 20mA current output, 10V loadcell excitation and an input sensitivity of 2.0mV/V for full range. |