SD039 Integral Loadmeter

This small loadmeter is designed for mounting in modified strain gauge loadcells.

It has an 8mm LED display for easy reading in poor light conditions. The loadmeter has push button tare and peak hold. When it is calibrated the update rate can be set to one of eight values to give some signal filtering to improve the display stability.

The sizes of the loadmeter board and the battery enclosure that we often use are shown below with a picture of a typical installation. If you have a project that requires a loadmeter to be mounted in a loadcell please consult our engineering department to discuss the possibilities.

It has an 8mm LED display for easy reading in poor light conditions. The loadmeter has push button tare and peak hold. When it is calibrated the update rate can be set to one of eight values to give some signal filtering to improve the display stability.

The sizes of the loadmeter board and the battery enclosure that we often use are shown below with a picture of a typical installation. If you have a project that requires a loadmeter to be mounted in a loadcell please consult our engineering department to discuss the possibilities.

Specification

ParameterValueUnit
Battery voltage9 (Min) / 14 (Max)V
Operating current40mA
Typical battery life - PP310hr
Operating temperature range-40 (Min) / 85 (Max)°C
Reverse polarity protection-30 (Max)V
Bridge excitation4.75 (Min) / 5.0 (Typical) / 5.25 (Max)V
Bridge Impedance350 (Min) / 5000 (Max)
Bridge sensitivity-7.0 (Min) / +7.0 (Max)mV/V
Filtering - 8 ranges40 (Min) / 500 (Max)ms
Nonlinearity0.002%FR
Zero temperature stability0.1±µV/°C
Span temperature stability0.001±%FR/°C

Order Codes

CodeDescription
In most cases the SD039 will be supplied in a special version of a loadcell that will have a Z number code. For a new design we normally supply the required code number at the time of order.
CE - This instrumentation product complies with the requirements of the European EMC directive.

Notes

  • FR = Full Range
  • The supply current depends on the loadcell bridge resistance.
  • The operating temperature range will depend on the battery used. As an example a typical Alkaline PP3 battery temperature range is -20 to 54°C.
  • The loadmeter specifications must be read in conjunction with the appropriate loadcell data-sheet to determine the overall specification of the loadcell and loadmeter combined.
  • Recalibration or changing the filter settings requires opening the loadcell to gain access to board mounted switches.

Files

TitleTypeFile
Outline drawing of the product.Outline Download
Outline drawing of the product.Outline 2 Download

Enquire about SD039 Integral Loadmeter

Related Products

TR150 Portable Loadmeter

The TR150 is a completely portable, precision instrument packaged in a small, robust IP65 (NEMA 4) enclosure, weighing only 260 grams. The TR150 accepts an input range of up to 50mV/V.

DSC USB Loadcell Digitiser

The DSC USB is a compact, high performance digital signal conditioner with USB connectivity aimed at applications, which require high-accuracy measurement repeatability.

FSU-SSBD Fast Loadcell Digitiser

The FSU-SSBD is a fast, compact, high precision loadcell input module delivering high resolution readings over USB and communicated directly to a PC.

SGA/A and SGA/D Loadcell Amplifier

The SGA loadcell amplifier is designed for use with strain gauge loadcells. It provides industry standard current or voltage outputs for accurate interfacing of loadcells with control and monitoring systems.

ICA6H Loadcell Amplifier

This miniature loadcell amplifier is designed for use with strain gauge loadcells. It has a bi-polar ±10V output for use with bi-directional loadcells even though it is powered from a uni-polar supply.

LCA20 Loadcell Amplifier

The LCA15 has been redesigned to become the LCA20 taking advantage of new technology to improve performance and increase functionality.

LCD20 Loadcell Amplifier

The LCD20 intelligent loadcell amplifier is a compact, DIN rail mounted microprocessor based unit for use with strain gauge bridge loadcells in force measuring applications.

TLB DIN rail mounted digital loadcell amplifier

TLB DIN rail mounted digital loadcell amplifier

TLM8 Multi-input digital loadmeter

TLM8 Multi-input digital loadmeter

WLIGHT portable digital loadmeter

WLIGHT portable digital loadmeter

W200 digital loadmeter

W200 digital loadmeter

INT4-L

The versatile INT4-L panel mount loadmeter for strain gauge loadcells

T24-ACM/SA Loadcell Telemetry Data Acquisition Unit

This remote loadcell data acquisition unit provides high performance wireless measurement of loadcell outputs. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells.

T24-ACMi/SA Miniature Loadcell Telemetry Data Acquisition Unit

This miniature loadcell data acquisition unit provides high performance wireless measurement of loadcell outputs. Providing direct mV/V input and 5V bridge excitation for up to 4 load cells.

T24-BSu Loadcell Telemetry Base Station

The base station is a computer interface for the T24 telemetry system that connects to a standard USB port on a computer. It is required for the configuration of all T24 modules.

T24-HA Handheld Telemetry Display Unit

This wireless handheld display module provides an 8 digit LCD reading from up to twelve T24 loadcell data acquisition modules.

T24-HS Handheld Telemetry Display Unit

This wireless handheld display module provides an 8 digit LCD reading from a T24 loadcell data acquisition module.

T24-SYS Loadcell Telemetry System

The T24 telemetry range is a flexible radio telemetry system designed to provide high accuracy measurement data from strain gauge loadcells.

T24-SYSC Set-up Wheel Loadcell Telemetry System

The T24 telemetry range is a flexible radio telemetry system designed to provide high accuracy measurement data from strain gauge loadcells.

SMW Intelligent Loadmeter

This panel or wall mounting loadmeter is designed for use with strain gauge loadcells.

ADW15 Loadmeter

This intelligent self contained loadmeter is designed for use with strain gauge loadcells.

SY011 Loadcell Amplifier

This loadcell amplifier is designed for use with strain gauge loadcells.

SY014 Integral Loadcell Amplifier

This loadcell amplifier is designed for mounting inside the F256 and F257 loadcells.

SY018 Loadcell Amplifier

This DIN rail mounted loadcell amplifier is designed for use with strain gauge loadcells.

SD039 Integral Loadmeter