F304 Brake Pedal Force Loadcell
Standard Range 2.5kN (250kgf)
- Off centre loading compensation
- Simple cable tie or screw fixing
- Anti-slip rubber pad
- Removable loading plate
- Output rationalised to 2mV/V
- Traceable calibration with certificate included in the standard price
Specification
Parameter | Value | Unit |
Non-linearity - Terminal | ±0.05 | % RL |
Hysteresis | ±0.05 | % RL |
Creep - 20 minutes | ±0.05 | % AL |
Repeatability | ±0.02 | % RL |
Rated output - Rationalised | 2.0 | mV/V |
Rationalisation tolerance | ±0.1 | % RL |
Zero load output | ±4 | % RL |
Temperature effect on rated output per °C | ±0.005 | % AL |
Temperature effect on zero load output per °C | ±0.005 | % RL |
Temperature range - Compensated | -10 to +50 | °C |
Temperature range - Safe | -10 to +80 | °C |
Excitation voltage - Recommended | 10 | V |
Excitation voltage - Maximum | 20 | V |
Bridge resistance | 700 | Ω |
Insulation resistance - Minimum at 50Vdc | 500 | MΩ |
Inclined load error - concentric at 3° | ±0.25 | % RL |
Structural stiffness | 3.9 x 107 | N/m |
Overload - Safe | 50 | % RL |
Overload - Ultimate | 200 | % RL |
Sideload - Safe | 100 | % RL |
Sealing | IP65 | |
Weight - Nominal (excluding cable) | 210 | g |
The standard range is manufactured in stainless steel.
The F304 is a compact, low profile loadcell for measuring brake pedal application forces.
The loadcell is robust in construction with a maximum force range of 2500N (250kgf). Its multi-hole fixing allows simple attachment to any shape pedal using screws or cable ties. The low profile stainless steel design maintains the brake pedals ergonomic geometry.
Additional information can be found in Engineering Sheet E030. If you require other force ranges the F322 or F323 may be suitable.
We are happy to design variants of this loadcell to meet your specific requirements. Versions can be manufactured for fully compensated operation up to +250°C. Please consult our engineering department.
Order Codes
Code | Description |
F304CFR0KN | Compression, IP65, rationalised |
Notes
- AL = Applied load.
- RL = Rated load.
- Temperature coefficients apply over the compensated range.
Connections
The loadcell is fitted with 2 metres of flexible polyurethane jacketed 4 core screened cable.
Excitation + = Red, Excitation - = Blue, Signal + = Yellow, Signal - = Green, Screen = Orange.
The screen is not connected to the loadcell body.