Precision force measurement sensor calibration you can trust
Novatech Measurements Ltd is UKAS-accredited for the calibration of force measuring devices, including strain gauged load cells, in accordance with BS 8422:2003.
Our calibration laboratory is accredited by the United Kingdom Accreditation Service (UKAS) to ISO/IEC 17025:2017, under accreditation number 31344.
https://www.ukas.com/download-schedule/31344/Calibration/
Combining specialist knowledge of force measurement with an accredited calibration process, Novatech provides confidence in the performance, accuracy and reliability of your force measurement equipment.
Whether you require calibration of an individual load cell or support maintaining the measurement integrity of your equipment, our experienced team can help.
Contact Novatech Measurements Ltd today to discuss your calibration requirements.
Our accredited scope covers force measuring devices operating in tension and compression with rated loads between 1 – 1000kN and compression only devices between 1 – 2000kN
Calibration is performed in accordance with BS 8422:2003, providing a recognised standard for the calibration of force measuring devices. Our accreditation is specific to the activities, measurement ranges and uncertainties detailed in our UKAS Schedule of Accreditation.
| Calibration Machine | Calibration Mode | Accredited Range | Expanded Measurement Uncertainty (k = 2) |
|---|---|---|---|
| Machine A | Compression only | 1 – 100 kN | ±0.29% |
| Machine B | Tension and compression | 2.5 – 800 kN | ±0.29% |
| Machine C | Tension and compression | 30 – 1,000 kN | ±0.29% |
| Machine C | Compression only | 200 – 2,000 kN | ±0.36% |
| Machine D | Tension and compression | 1 – 100 kN | ±0.29% |
FAQ's
What is UKAS accreditation?
UKAS accreditation provides independent recognition from the United Kingdom Accreditation Service of a laboratory’s competence to undertake specific calibration activities. These activities are proven to have an unbroken and fully traceable link through other UKAS accredited companies, ensuring that the equipment used is maintained to a sufficient standard to justify the uncertainty value given in the schedule of accreditation.
What is a UKAS accredited calibration?
UKAS accredited calibrations are those performed by a laboratory independently assessed by the United Kingdom Accreditation Service for technical competence against the requirements of ISO/IEC 17025. UKAS calibrations can only be offered by companies that have achieved UKAS accreditation.
What is ISO/IEC 17025:2017?
ISO/IEC 17025:2017 is the international standard specifying the general requirements for the competence, impartiality and consistent operation of testing and calibration laboratories.
What is BS 8422:2003?
BS 8422:2003 is a British Standard that sets out a specific methodology for the calibration of force measuring devices. This includes the minimum number of calibration runs, data points, and environmental conditions that must be met for qualifying calibration.
What does Expanded Measurement Uncertainty mean?
The expanded measurement uncertainty is a standard deviation value, derived from the merged individual contributing factors of anything that could affect the confidence in the stated values on any calibration certificates. This may include the exact value of the applied force, measurement resolution, thermal effects and operator influence. A coverage factor of 2 is used to provide a 95% confidence that the stated calibration values fall within the maximum error band given in the accreditation schedule.
The error band applies only to the correlation between the uncertainty of the applied force and the recorded final mV/V value using equipment owned and maintained by Novatech. The actual uncertainty applicable to an individual calibration may be affected by the general condition, performance and characteristics of the user owned device being calibrated.
Why choose Novatech Measurements?
Novatech is not just a calibration laboratory but also an established bespoke manufacturer with specialist force measurement knowledge. Novatech has extensive experience in complex load cell design, manufacture, calibration and repair and operates at the forefront of force measurement technology. This specialist knowledge provides a valuable understanding of the equipment being calibrated as well as its intended application that other providers acting solely as calibration laboratories may lack.
Can you calibrate equipment at our premises?
Our current UKAS accreditation specifies that calibration is performed at Novatech’s laboratory in St. Leonards-on-Sea, East Sussex. On-site calibration at customer premises is not included in this accredited scope.
Are all Novatech calibration services UKAS accredited?
No. UKAS accreditation applies only to the activities specifically listed in our accreditation schedule. We also provide lower range force calibrations and a wide range of torque and multi-axis calibrations that are not UKAS accredited. These calibrations do not follow the methodology of BS 8422:2003 but use most of the same equipment that is maintained to the highest standard for UKAS accredited work. As such, we can offer non-accredited calibrations with a very similar level of confidence in the overall measurement uncertainty. Further details of our other calibration capabilities can be found at the link below
How do I Request a calibration quotation?
If you require UKAS-accredited calibration of a load cell, load measuring ring or other force measuring device, our team will be happy to discuss your requirements.
To help us assess your calibration requirements, please provide the following details:
- Equipment type, model number and manufacturer.
- Maximum force capacity and required calibration range, if different.
- Required calibration mode (tension, compression or both).
- Any additional calibration or specific documentation requirements.
Our team can then advise whether your equipment falls within our accredited scope and assist with the next steps.
Contact Novatech today to arrange your UKAS-accredited load cell calibration.
Novatech Measurements Limited
Telephone: +44 (0)1424 852744
Email: info@novatechloadcells.co.uk
Website: www.novatechloadcells.co.uk