F319 Handbrake Loadcell

Standard Range 1kN (100kgf)
The F319 handbrake loadcell offers an excellent technical solution to measurement of an ergonomic force.

The double shear web design and rigid low profile finger grip combine to maintain the same precision of measurement along the entire finger grip length. The typical unevenly distributed force applied by the human hand is measured with good repeatability and minimum error in a sense normal to the lever axis.

The F319 has been fitted directly to a handbrake lever and also adapted for production tests by using an easy fit socket moulding, as care must be taken to ensure that the hand clamping forces are not measured in addition to the handbrake pull force the moulding used a ‘dorsal fin’ to ensure hand clamping was avoided.

Application TestsUneven Hand Loading Errors

The uneven load distribution of a human hand has been replicated by applying point loads over the length of the loadcell. In the worst case, the extreme ends, the error is limited to <1% of the applied force.

Handbrake Angle Vector Errors

The F319 handbrake loadcell measures force perpendicular or normal to the handbrake lever. Variations of lever inclination angle can produce angular deviations between the applied force and the loadcell’s normal measurement axis. For angular deviations up to 33° to the loadcell’s normal axis the load errors are limited to <1% of the applied force.

The double shear web design and rigid low profile finger grip combine to maintain the same precision of measurement along the entire finger grip length. The typical unevenly distributed force applied by the human hand is measured with good repeatability and minimum error in a sense normal to the lever axis.

The F319 has been fitted directly to a handbrake lever and also adapted for production tests by using an easy fit socket moulding, as care must be taken to ensure that the hand clamping forces are not measured in addition to the handbrake pull force the moulding used a ‘dorsal fin’ to ensure hand clamping was avoided.

Application TestsUneven Hand Loading Errors

The uneven load distribution of a human hand has been replicated by applying point loads over the length of the loadcell. In the worst case, the extreme ends, the error is limited to <1% of the applied force.

Handbrake Angle Vector Errors

The F319 handbrake loadcell measures force perpendicular or normal to the handbrake lever. Variations of lever inclination angle can produce angular deviations between the applied force and the loadcell’s normal measurement axis. For angular deviations up to 33° to the loadcell’s normal axis the load errors are limited to <1% of the applied force.

Specification

ParameterValueUnit
Non-linearity - Terminal±0.05% RL
Hysteresis±0.05% RL
Creep - 20 minutes±0.1% AL
Repeatability±0.02% RL
Rated output - Rationalised1.0mV/V
Rationalisation tolerance±0.2% RL
Zero load output±4% RL
Temperature effect on rated output per °C±0.005% AL
Temperature effect on zero load output per °C±0.01% RL
Temperature range - Compensated-10 to +50°C
Temperature range - Safe-10 to +80°C
Excitation voltage - Recommended10V
Excitation voltage - Maximum10V
Bridge resistance350
Insulation resistance - Minimum at 50Vdc500MΩ
Structural stiffness - Nominal1.4 x 107N/m
Overload - Safe50% RL
Overload - Ultimate100% RL
SealingIP65

Order Codes

CodeDescription
F319CFR0HNCompression, IP65, rationalised

Notes

  • AL = Applied load.
  • RL = Rated load.
  • Temperature coefficients apply over the compensated range.

Connections

The F319 loadcell is fitted with 2 metres of PVC insulated 4 core screened cable type 7-1-4C. The cable is connected to the loadcell with a miniature 4 pin connector so that cable can be easily replaced if it is damaged.

Excitation + = Red, Excitation – = Blue, Signal + = Yellow, Signal – = Green, Screen = Orange.

The screen is not connected to the loadcell body.

Files

TitleTypeFile
Outline drawing of the product.Outline Download
F319CFR0H0 1kN (100kgf)STEP File Download

Enquire about F319 Handbrake Loadcell

Related Products

Bending Beam Load Cell for Set-up Wheel Assembly
  • Capacity / Rated Load: 1.25 – 5kN
  • Non – Linearity: 0.05%RL
  • Special Features: High Level of Compensation for Off-Axis Forces. Ideal for Variable Camber Angles
Low Range Pedal Force Load Cell
  • Capacity / Rated Load: 250N
  • Non – Linearity: 0.05%RL
  • Special Features: Dual Fixing Options for Increased Versatility. Can Withstand Off-Centre Load
Medium Range Pedal Force Load Cell
  • Capacity / Rated Load: 1kN
  • Non – Linearity: 0.05%RL
  • Special Features: Dual Fixing Options for Increased Versatility. Can Withstand Off-Centre Load
High Range Pedal Force Load Cell
  • Capacity / Rated Load: 2.5kN
  • Non – Linearity: 0.05%RL
  • Special Features: Dual Fixing Options for Increased Versatility. Can Withstand Off-Centre Load
Belt Tension Load Cell
  • Capacity / Rated Load: 16kN
  • Non – Linearity: 3.0%RL
  • Special Features: Lightweight Construction to Avoid Influence During Crash Testing
  • Custom Options: Custom Force Ranges and Designs to Suit Specific Belt Width and Thicknesses
Handbrake Load Cell
  • Capacity / Rated Load: 1kN
  • Non – Linearity: 0.05%RL
  • Special Features: Ergonomic Design. Can Withstand Off-Centre Load and Variable Moment Arm
3-Axis Gear Shift Load Cell
  • Capacity / Rated Load: 200N
  • Non – Linearity: 0.5%RL
  • Special Features: Ergonomic Design. Direct Replacement of Existing Part
  • Custom Options: Custom Force Ranges / Dimensions and Single or 2-Axis Versions Available